Troubleshooting – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 133

Advertising
background image

9 - 9

9. TROUBLESHOOTING

Display

Name

Definition

Cause

Action

1. Pulse frequency of the command

pulse is too high.

Change the command pulse frequency to a
proper value.

2. Noise entered command pulses.

Take action against noise.

A. 35

Command
pulse frequency
error

Input pulse
frequency of the
command pulse is
too high.

3. Command device failure

Change the command device.

A. 37

Parameter
error

Parameter setting is
wrong.

Servo amplifier fault caused the
parameter setting to be rewritten.

Change the servo amplifier.

1. Servo amplifier is used in excess

of its continuous output current.

1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger

output.

2. Servo system is instable and

hunting.

1. Repeat acceleration/

deceleration to execute auto tuning.

2. Change auto tuning response setting.
3. Set auto tuning to OFF and make gain

adjustment manually.

3. Machine struck something.

1. Review operation pattern.
2. Install limit switches.

4. Wrong connection of servo motor.

Servo amplifier's output terminals
U, V, W do not match servo
motor's input terminals U, V, W.

Connect correctly.

A. 50

Overload 1

Load exceeded
overload protection
characteristic of
servo amplifier.
Load ratio 200%:

85s or more

5. Encoder faulty.

When the servo motor shaft is
rotated slowly with the servo off,
the cumulative feedback pulses
should vary in proportion to the
rotary angle. If the indication
skips or returns midway, the
encoder is faulty.

Checking method

Change the servo motor.

Advertising