2 - 1

2. INSTALLATION

2. INSTALLATION

CAUTION

y Stacking in excess of the limited number of products is not allowed.
y Install the equipment to incombustible. Installing them directly or close to

combustibles will led to a fire.

y Install the equipment in a load-bearing place in accordance with this Instruction

Manual.

y Do not get on or put heavy load on the equipment to prevent injury.
y Use the equipment within the specified environmental condition range.
y Provide an adequate protection to prevent screws, metallic detritus and other

conductive matter or oil and other combustible matter from entering the servo

amplifier.

y Do not block the intake/exhaust ports of the servo amplifier. Otherwise, a fault may

occur.

y Do not subject the servo amplifier to drop impact or shock loads as they are

precision equipment.

y Do not install or operate a faulty servo amplifier.
y When the product has been stored for an extended period of time, consult

Mitsubishi.

2.1 Environmental conditions

Environment

Conditions

0 to +55 [

°

C] (non-freezing)

Ambient temperature

32 to +131 [

°

F] (non-freezing)

Ambient humidity

90%RH or less (non-condensing)

20 to +65 [

°

C] (non-freezing)

storage temperature

4 to +149 [

°

F] (non-freezing)

storage humidity

90%RH or less (non-condensing)

Ambient

Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt

Altitude

Max. 1000m (3280 ft) above sea level
5.9 [m/s

2

] {0.6G} or less

Vibration

19.4 [ft/s

2

] or less