Parameters – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 87

Advertising
background image

5 - 10

5. PARAMETERS

Class

No.

Symbol

Name and Function

Initial

Value

Unit

Setting

Range

Control

Mode

S

20

*OP2 Function selection 2:

Used to select restart after instantaneous power failure,
servo lock at a stop in speed control mode, and slight vibration
suppression control.

0: Invalid
1: Valid

If the input power supply voltage
had reduced in the speed control
mode to stop the servo motor due
to the undervoltage alarm (A. 10)
but the supply voltage has return-
ed to normal, the servo motor can
be restarted by merely switching
on the start signal without resett-
ing the alarm.

Restart after instantaneous
power failure

Stop-time servo lock selection

The shaft can be servo-locked to
remain still at a stop in the speed
control mode.

0: Valid
1: Invalid

Slight vibration suppression control

Used to suppress vibration at a stop.

0: Invalid
1: Valid

0

0000

0000h

to

0111h

P

E

xp

ansio

n p

aram

ete

rs

21

*OP3 Function selection 3 (Command pulse selection) :

Used to select the input form of the pulse train input signal.
(Refer to Section 3.4.1.)

Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A/B phase pulse train

Pulse train logic selection
0: Positive logic
1: Negative logic

0

0

0000

0000h

to

0012h

P

Advertising