(4) Usage

CAUTION

y Provide an external emergency stop circuit to ensure that operation can be stopped and power switched off

immediately.

y Any person who is involved in disassembly and repair should be fully competent to do the work.

y Before resetting an alarm, make sure that the run signal is off to prevent an accident. A sudden restart is

made if an alarm is reset with the run signal on.

y Do not modify the equipment.

y Use a noise filter, etc. to minimize the influence of electromagnetic interference, which may be caused by

electronic equipment used near the servo amplifier.

y Use the servo amplifier with the specified servo motor.

y The electromagnetic brake on the servo motor is designed to hold the motor shaft and should not be used

for ordinary braking.

y For such reasons as service life and mechanical structure (e.g. where a ballscrew and the servo motor are

coupled via a timing belt), the electromagnetic brake may not hold the motor shaft. To ensure safety, install

a stopper on the machine side.

(5) Corrective actions

CAUTION

y When it is assumed that a hazardous condition may take place at the occur due to a power failure or a

product fault, use a servo motor with electromagnetic brake or an external brake mechanism for the

purpose of prevention.

y When any alarm has occurred, eliminate its cause, ensure safety, and deactivate the alarm before

restarting operation.

y When power is restored after an instantaneous power failure, keep away from the machine because the

machine may be restarted suddenly (design the machine so that it is secured against hazard if restarted).

(6) Maintenance, inspection and parts replacement

CAUTION

y With age, the electrolytic capacitor will deteriorate. To prevent a secondary accident due to a fault, it is

recommended to replace the electrolytic capacitor every 10 years when used in general environment.