6 external input signal on/off (test operation), Communication functions – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 176

Advertising
background image

13 - 20

13. COMMUNICATION FUNCTIONS

13.12.6 External input signal ON/OFF (Test operation)

Each input signal can be turned on/off for test operation. Turn off the external input signals.

Send command [9] [2], data No. [0] [0] and data.

Command

Data No.

Set Data

[9] [2]

[0] [0]

See below

b31

b0

0: OFF

1: ON

b1

Command of each bit is transmitted to the slave
station as hexadecimal data.

bit

Signal Abbreviation

bit

Signal Abbreviation

bit

Signal Abbreviation

bit

Signal Abbreviation

0

SON

8

16

24

1

LSP

9

17

25

2

LSN

10

18

26

3

TL

11

19

27

4

12

20

28

5

PC

13

21

29

6

RES

14

22

30

7

CR

15

23

31