Parameters – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 88

Advertising
background image

5 - 11

5. PARAMETERS

Class

No.

Symbol

Name and Function

Initial

Value

Unit

Setting

Range

Control

Mode

E

xp

ansio

n p

aram

ete

rs

22

*OP4 Function selection 4:

Used to select stop processing at LSP/LSN signal off and choose the
machine resonance suppression filter.

Machine resonance suppression filter

How to make a stop when LSP/LSN
signal is valid.
0: Sudden stop
1: Slow stop

In the position control mode,
the servo motor is decelerated
to a stop according to parameter
No. 7 setting.
In the speed control mode,
the servo motor is decelerated
to a stop according to parameter
No. 12 setting.

Set Value

0

1

2

Filtering Time [ms]

0

1.77

3.55

3

7.11

Set Value

0

1

2

Notch Frequency [Hz]

Not used

1125

563

3

375

4

5

6

282

225

188

7

161

0

VC/VLA voltage averaging

Used to set the filtering time when the
analog speed command (VC) voltage or
analog speed limit (VLA) is imported.
Set 0 to vary the speed to voltage fluctua-
tion in real time. Increase the set value
to vary the speed slower to voltage flu-
ctuation.

0000

0000h

to

7301h

P x S x T

Advertising