Troubleshooting – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 127

Advertising
background image

9 - 3

9. TROUBLESHOOTING

(2) How to find the cause of position shift

Positioning unit

(a) Output pulse
counter

Q

P

CMX

CDV

(C) Servo on (SON),
stroke end
(LSP/LSN) input

(A)

(b) Cumulative command
pulses

Electronic gear (parameters No. 3, 4)

C

Servo moter

SM

Encoder

L

Machine

(d) Machine stop
position M

(B)

(c) Cumulative
feedback pulses

Servo amplifier

When a position shift occurs, check (a) output pulse counter, (b) cumulative command pulse display, (c)
cumulative feedback pulse display, and (d) machine stop position in the above diagram.
(A), (B) and (C) indicate position shift causes. For example, (A) indicates that noise entered the wiring
between positioning unit and servo amplifier, causing pulses to be mis-counted.

In a normal status without position shift, there are the following relationships:

1) Q = P (positioning unit's output counter = servo amplifier's cumulative command pulses)

2) P x

(

)

(

)

4

No.

parameter

CDV

3

No.

parameter

CMX

= C (cumulative command pulses

×

electronic gear = cumulative feedback pulses)

3) C x

l = M (cumulative feedback pulses

×

travel per pulse = machine position)

Check for a position shift in the following sequence:

1) When Q

P

Noise entered the pulse train signal wiring between positioning unit and servo amplifier, causing
pulses to be miss-counted. (Cause A)
Make the following check or take the following measures:

Check how the shielding is done.
Change the open collector system to the differential line driver system.
Run wiring away from the power circuit.
Install a data line filter. (Refer to Section 12.2.4.)

2) When P x

CDV

CMX

C

During operation, the servo on signal (SON) or forward/reverse rotation stroke end signal was
switched off or the clear signal (CR) and the reset signal (RES) switched on. (Cause C)
If a malfunction may occur due to much noise, increase the input filter setting (parameter No. 1).

3) When C x

l

M

Mechanical slip occurred between the servo motor and machine. (Cause B)

Advertising