3 remedies for warnings, Troubleshooting – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 135

Advertising
background image

9 - 11

9. TROUBLESHOOTING

Display

Name

Definition

Cause

Action

1. Communication cable fault

(Open cable or short circuit)

Repair or change the cable.

A. 8E

Serial
communication
error

Serial
communication
error occurred
between servo
amplifier and
communication
device (e.g. personal
computer).

2. Communication device (e.g.

personal computer) faulty

Change the communication device (e.g.
personal computer).

8888

Watchdog

CPU, parts faulty

Fault of parts in servo amplifier

Alarm (8888) occurs if power is
switched on after connectors
CN1A, CN1B, CNP2, CNP3 are
disconnected.

Checking method

Change servo amplifier.

9.2.3

Remedies for Warnings

If A.E1 (overload warning) occurs, operation may be continued but an alarm may take place or proper
operation may not be performed. If another warning (A.E6 or A.E9) occurs, the servo amplifier will go into
a servo-off status. Eliminate the cause of the warning according to this section. Use the optional Servo
Configuration software to refer to the cause of warning.

Display

Name

Definition

Cause

Action

A. E1

Overload
warning

There is a possibility that
overload alarm 1 or 2 may
occur.

Load increased to 85% or more of
overload alarm 1 or 2 occurrence level.

Cause, checking method

Refer to A. 50, 51.

Refer to A. 50, A. 51.

A. E6

Servo forced stop EMG-SG are open.

External forced stop was made valid.
(EMG-SG opened.)

Ensure safety and deactivate
forced stop.

A. E9

Main circuit off
warning

Servo was switched on
with main circuit power
off.

Switch on main circuit power.

Advertising