7 input power supply circuit, 1 connection example, Signals and wiring – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 65: Caution

Advertising
background image

3 - 40

3. SIGNALS AND WIRING

3.7 Input Power Supply Circuit

CAUTION

y When the servo amplifier has become faulty, switch power off on the servo

amplifier power side. Continuous flow of a large current may cause a fire.

3.7.1

Connection example

+

24VDC

1

2

3

15

10

3

13

18

RA2

OFF

RA1

ON

RA1

RA2

RA2

P24M

P24G

P24L

EMG

SG

CNP1

CN1B

VDD

COM

ALM

CN1B

1

2

3

15

10

3

13

18

RA4

OFF

RA3

ON

RA3

RA4

RA4

P24M

P24G

P24L

EMG

SG

CNP1

CN1B

VDD

COM

ALM

CN1B

1

2

3

15

10

3

13

18

RA6

OFF

RA5

ON

RA5

RA6

RA6

P24M

P24G

P24L

EMG

SG

CNP1

CN1B

VDD

COM

ALM

CN1B

Forced

stop

Servo amplifier

Circuit
protector

Circuit
protector

Forced

stop

Servo amplifier

Forced

stop

Circuit
protector

Servo amplifier

Note: 1. When using an electromagnetic brake, determine the power supply by taking the rated current

value of the electromagnetic brake into consideration.

2. Configure up the power supply circuit which will switch off power upon detection of alarm

occurrence.

Advertising