Display and operation – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 107

Advertising
background image

6 - 9

6. DISPLAY AND OPERATION

(a) Control modes and I/O signals

(Note 2) Symbols of I/O Signals in Control Modes

Connector

Pin No.

Signal

Input/Output

(Note 1) I/O

P

P/S

S

S/T

T

T/P

8

I

CR

CR/SP1

(Note 3)

SP1

SP1

(Note 3)

SP1

SP1/CR

14

O

OP

OP

OP

OP

OP

OP

(Note 6, 8) 18

O

INP

INP/SA

SA

SA/

/INP

CN1A

(Note 8) 19

O

RD

RD

RD

RD

RD

RD

(Note 9) 4

O

DO1

DO1

DO1

DO1

DO1

DO1

(Note 7) 5

I

SON

SON

SON

SON

SON

SON

(Note 6) 6

O

TLC

TLC

TLC

TLC/VLC

VLC

VLC/TLC

(Note 7) 7

I

LOP

SP2

LOP

SP2

LOP

(Note 7) 8

I

PC

PC/ST1

(Note 4)

ST1

ST1/RS2

(Note 4)

RS2

RS2/PC

(Note 7) 9

I

TL

TL/ST2

(Note 5)

ST2

ST2/RS1

(Note 5)

RS1

RS1/TL

(Note 7) 14

I

RES

RES

RES

RES

RES

RES

15

I

EMG

EMG

EMG

EMG

EMG

EMG

16

I

LSP

LSP

LSP

LSP/

/LSP

17

I

LSN

LSN

LSN

LSN/

/LSN

(Note 6) 18

O

ALM

ALM

ALM

ALM

ALM

ALM

CN1B

(Note 6, 8) 19

O

ZSP

ZSP

ZSP

ZSP

ZSP

ZSP

CNP2

9

O

B1

B1

B1

B1

B1

B1

Note:1. I : Input signal, O: Output signal

2. P : Position control mode, S: Speed control mode, T: Torque control mode, P/S: Position/speed control change mode, S/T:

Speed/torque control change mode, T/P: Torque/position control change mode

3. Set parameter No. 45 to use CR.
4. Set parameter No. 47 to use PC.
5. Set parameter No. 48 to use TL.
6. Set parameter No. 49 to use WNG.
7. Set parameters No. 43 to 48 to change signals.
8. Set parameter No. 49 to output the alarm code. (Refer to Section 9.2.1.)
9. The signal of CN1A-18 is always output.

(b) Symbol and signal names

Symbol

Signal Name

Symbol

Signal Name

SON

Servo-on

EMG

Forced stop

LSP

Forward rotation stroke end

LOP

Control change

LSN

Reverse rotation stroke end

TLC

Limiting torque

CR

Clear

VLC

Limiting speed

SP1

Speed selection 1

RD

Ready

SP2

Speed selection 2

ZSP

Zero speed

PC

Proportion control

INP

In position

ST1

Forward rotation start

SA

Speed reached

ST2

Reverse rotation start

ALM

Trouble

RS1

Forward rotation selection

WNG

Warning

RS2

Reverse rotation selection

OP

Encoder Z-phase pulse (open collector)

TL

Torque limit

B1

Electromagnetic brake

RES

Reset

Advertising