Parameters – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 86

Advertising
background image

5 - 9

5. PARAMETERS

Class

No.

Symbol

Name and Function

Initial

Value

Unit

Setting

Range

Control

Mode

18

*DMD Status display selection:

Used to select the status display shown at power-on.

Selection of status display at
power-on
0: Cumulative feedback pulses
1: Servo motor speed
2: Droop pulses
3: Cumulative command pulses
4: Command pulse frequency
5: Analog speed command voltage
(Note 1)
6: Analog torque command voltage
(Note 2)
7: Regenerative load ratio
8: Effective load ratio
9: Peak load ratio
A: Within one-revolution position
B: ABS counter
C: Load inertia moment ratio

0

0

In speed control mode. Analog
speed limit voltage in torque
control mode.
In torque control mode. Analog
torque limit voltage in speed or
position control mode.

Note: 1.

2.

Status display at power-on in
corresponding control mode
0: Depends on the control mode.

0000

0000h

to

001Ch

P x S x T

Control Mode

Position

Position/speed

Speed

Speed/torque

Torque

Torque/position

Status Display at Power-On

Cumulative feedback pulses

Cumulative feedback pulses/servo motor speed

Servo motor speed

Servo motor speed/analog torque command voltage

Analog torque command voltage

Analog torque command voltage/cumulative feedback pulses

1: Depends on the first digit setting of this parameter.

Parameter block:

Used to select the reference and write ranges of the parameters.

Set Value

Operation

Basic

Parameters

No. 0 to No. 19

Expansion

Parameters

No. 20 to No. 49

Reference

{

0000

(Initial value)

Write

{

Reference

No. 19 only

000A

Write

No. 19 only

Reference

{

{

000B

Write

{

Reference

{

{

000C

Write

{

{

B

asi

c p

ara

meters

19

*BLK

0000

0000h

to

000Ch

P x S x T