43

*DI2

Input signal selection 2 (CN1B-pin 5):

This parameter is unavailable when parameter No. 42 is set to assign
the control change signal (LOP) to CN1B-pin 5.
Allows any input signal to be assigned to CN1B-pin 5.
Note that the setting digit and assigned signal differ according to the
control mode.

0

Position
control mode

Input signals of
CN1B-pin 5
selected.

Torque control mode

Speed control
mode

Signals that may be assigned in each control mode are indicated
below by their symbols.

Set value

(Note) Control Mode

P

S

T

0
1
2
3
4
5
6
7
8
9

SON

SON

SON

RES

RES

RES

PC

PC

TL

TL

TL

SP1

SP1

SP2

SP2

ST1

RS2

ST2

RS1

CR

CR

CR

Note: P: Position control mode

S: Speed control mode
T: Torque control mode

0111

0000h

to

0999h

P x S x T

E

xp

ansio

n p

aram

ete

rs

44

*DI3

Input signal selection 3 (CN1B-pin 14):

This parameter is unavailable when parameter No. 42 is set to assign
the control change signal (LOP) to CN1B-pin 14.
Allows any input signal to be assigned to CN1B-pin 14.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).

0

Position
control mode

Input signals of
CN1B-pin 14
selected.

Torque control mode

Speed control
mode

0222

0000h

to

0999h

P x S x T

Advertising