Options and auxiliary equipment – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 156

Advertising
background image

12 - 14

12. OPTIONS AND AUXILIARY EQUIPMENT

(b) Cable clamp fitting (AERSBAN-†SET)

Generally, the earth of the shielded cable may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an earth plate as shown below.
Install the earth plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the earth plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the earth plate.

Srip the cable sheath of
athe clamped area.

cutter

cable

Cable clamp

(A,B)

Cable

Earth plate

External conductor

Clamp section diagram

40(1.

5

7

)

x

Outline drawing

2-

φ

5(0.20) hole

installation hole

Earth plate

Clamp section diagram

(Note)M4 screw

11(0.

4

3

)

3 (0

.12)

6 (0

.24)

C

A

6

22(0.87)

17.5(0.69)

35(1.38)

35 (

1

.38)

L or less

10(0.39)

30(1.

1

8

)

B

±

0.

3(

0.

01)

7 (0

.28)

24

0

-0.

2

Note: Screw hole for grounding. Connect it to

the earth plate of the control box.

(0.24)

24

+0

.3

0

(0.9

40

)

(0.9

40

)

[Unit: mm]

([Unit: in.])

Type

A

B

C

Accessory Fittings

Clamp Fitting

L

AERSBAN-DSET

100

(3.94)

86

(3.39)

30

(1.18)

clamp A: 2pcs.

A

70

(2.76)

AERSBAN-ESET

70

(2.76)

56

(2.20)

clamp B: 1pc.

B

45

(1.77)

Advertising