3 - 28

3. SIGNALS AND WIRING

(b) Speed selection 1 (SP1)/speed selection 2 (SP2) and speed command values

Choose any of the speed settings made by the internal speed limits 1 to 3 using speed selection 1
(SP1) and speed selection 2 (SP2) or the speed setting made by the speed limit command (VLA).

(Note) External Input Signals

SP2

SP1

Speed Command Value

0

0

Speed limit command (VLA)

0

1

Parameter No. 8

1

0

Parameter No. 9

1

1

Parameter No. 10

Note.0: SP1/SP2-SG off (open)

1: SP1/SP2-SG on (short)

When the internal speed commands 1 to 3 are used to command the speed, the speed does not vary
with the ambient temperature.

(c) Limiting speed (VLC)

TLC-SG are connected when the servo motor speed reaches the limit speed set to any of the internal
speed limits 1 to 3 or analog speed limit.