Parameters – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 84

Advertising
background image

5 - 7

5. PARAMETERS

Class

No.

Symbol

Name and Function

Initial

Value

Unit

Setting

Range

Control

Mode

Internal speed command 3:

Used to set speed 3 of internal speed commands.

S

10

SC3

Internal speed limit 3:

Used to set speed 3 of internal speed limits.

1000

r/min

0 to

instan-

taneous

permi-

ssible
speed

T

Acceleration time constant:

Used to set the acceleration time required to reach the rated speed
from zero speed in response to the analog speed command and
internal speed commands 1 to 3.

Time

Parameter
No.12 setting

Parameter
No.11 setting

Zero
speed

Rated
speed

Speed

If the preset command speed is
lower than the rated speed,
acceleration/deceleration time
will be shorter.

Example: Set 3000 (3s) to increase speed from 0r/min to 1000r/min in

1 second.

POINT

y

When configuring an external position loop, set 0 or minimal

values in parameters No. 11 and 12.

11

STA

0

12

STB

Deceleration time constant:

Used to set the deceleration time required to reach zero speed from
the rated speed in response to the analog speed command and
internal speed commands 1 to 3.

0

ms

0

to

20000

S x T

B

asi

c p

ara

meters

13

STC

S-pattern acceleration/deceleration time constant:

Used to smooth start/stop of the servo motor.

STA: Aeceleration time constant (parameter No.11)
STB: Deceleration time constant (parameter No.12)
STC: S-pattern acceleration/deceleration time con-
stant (parameter No.13)

Command speed

0r/min

STC

STA

STC

STC

STB STC

Time

0

ms

0

to

1000

S x T