6 - 4

6. DISPLAY AND OPERATION

6.3 Diagnostic mode

Name

Display

Description

Not ready.
Indicates that the servo amplifier is being initialized or an alarm
has occurred.

Sequence

Ready.
Indicates that the servo was switched on after completion of
initialization and the servo amplifier is ready to operate.

External I/O signal
display

Refer to section 6.6.

Indicates the ON-OFF states of the external I/O signals.
The upper segments correspond to the input signals and the
lower segments to the output signals.

Lit: ON
Extinguished: OFF

The I/O signals can be changed using parameters No. 43 to 49.

Output signal forced
output

The digital output signal can be forced on/off. For more
information, refer to section 6.7.

Jog feed

Jog operation can be performed when there is no command from
the external command device.
For details, refer to section 6.8.2

Positioning
operation

The servo configuration software (MRZJW3-SETUP61E) is
required for positioning operation. This operation cannot be
performed from the operation section of the servo amplifier.
Positioning operation can be performed once when there is no
command from the external command device.

Test
operation
mode

Motorless
operation

Without connection of the servo motor, the servo amplifier
provides output signals and displays the status as if the servo
motor is running actually in response to the external input
signal.
For details, refer to section 6.8.4.

Software version Low

Indicates the version of the software.

Software version High

Indicates the system number of the software.

Automatic VC offset

If offset voltages in the analog circuits inside and outside the
servo amplifier cause the servo motor to rotate slowly at the
analog speed command (VC) or analog speed limit (VLA) of 0V,
this function automatically makes zero-adjustment of offset
voltages.
When using this function, make it valid in the following
procedure. Making it valid causes the parameter No. 29 value to
be the automatically adjusted offset voltage.
1) Press "SET" once.
2) Choose 1 with "UP"/"DOWN".
3) Press "SET".