2 remedies for alarms, Troubleshooting, Caution – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 131

Advertising
background image

9 - 7

9. TROUBLESHOOTING

9.2.2

Remedies for alarms

CAUTION

y When any alarm has occurred, eliminate its cause, ensure safety, then reset the

alarm, and restart operation. Otherwise, injury may occur.

POINT

y

When any of the following alarms has occurred, always remove its cause and

allow about 15 minutes for cooling before resuming operation. If operation is
resumed by switching control circuit power off, then on to reset the alarm,
the servo amplifier and servo motor may become faulty.
x

Overload 1 (A. 50)

x

Overload 2 (A. 51)

y

The alarm can be deactivated by switching power off, then on or by turning

on the reset signal (RES). For details, refer to Section 9.2.1.

When an alarm occurs, the trouble signal (ALM) switches off and the dynamic brake is operated to stop the
servomotor. At this time, the display indicates the alarm No.
The servo motor comes to a stop. Remove the cause of the alarm in accordance with this section. The
optional Servo Configuration Software may be used to refer to the cause.

Display

Name

Definition

Cause

Action

1. Power supply voltage is low.
2. Power failed instantaneously for

15ms or longer.

3. Shortage of power supply capacity

caused the power supply voltage to
drop at start, etc.

4. Power switched on within 5s after

it had switched off.

Review the power supply.

A. 10

Undervoltage

Power supply
voltage dropped to
20V or less

5. Faulty parts in the servo amplifier

Alarm (10) occurs if power is
switched on after connectors
CN1A, CN1B, CNP2, CNP3
are disconnected.

Checking method

Change the servo amplifier.

A. 11

Board error 1

Printed board faulty

A. 12

Memory error 1 RAM, ROM memory

fault

A. 13

Clock error

Printed board fault

A. 15

Memory error 2 EEPROM fault

Faulty parts in the servo amplifier

Alarm (any of 11 to 13 and 15)
occurs if power is switched on
after connectors CN1A, CN1B,
CNP2, CNP3 are disconnected.

Checking method

Change the servo amplifier.

1. CNP2 connector disconnected.

Connect correctly.

2. Encoder fault

Change the servo motor.

A. 16

Encoder error 1 Communication

error occurred
between encoder
and servo amplifier.

3. Motor cable faulty

(Encoder wiring broken or shorted)

Repair or change cable.

Advertising