13. COMMUNICATION FUNCTIONS

13. COMMUNICATION FUNCTIONS

The MR-J2-03A5 has the RS-422 and RS-232C serial communication functions. These functions can be
used to perform servo operation, parameter changing, monitor function, etc.
However, the RS-422 and RS-232C communication functions cannot be used together. Select between RS-
422 and RS-232C with parameter No.16. (Refer to Section 5.2.5.)
This function is also available for RS-485. Make the same connections, settings, etc. as in RS-422.

13.1 Configuration

13.1.1 RS-422 configuration

(1) Outline

Up to 32 axes of servo amplifiers from stations 0 to 31 can be operated on the same bus.

Axis 32 (Station 31)

MITSUBISHI

OPEN

CN1A

CN1B

CNP1

CNP2

CNP3

MELSERVO

MITSUBISHI

OPEN

CN1A

CN1B

CNP1

CNP2

CNP3

MELSERVO

MITSUBISHI

OPEN

CN1A

CN1B

CNP1

CNP2

CNP3

MELSERVO

Controller such as
personal computer

RS-232C
/RS-422
converter

RS-422

Axis 1 (Station 0)

Unavailable as option
To be prepared by customer.

To CNP1

Servo amplifier

Axis 2 (Station 1)

To CNP1

Servo amplifier

To CNP1

Servo amplifier

(2) Cable connection diagram

Wire as shown below:

(Note 3)30m max.

(Note 1)

Axis 2 servo amplifier

CNP1 connector

(Note 1)

Axis 1 servo amplifier

CNP1 connector

RS-422
output unit

(Note2)

RDP

RDN

SDP

LG

SDN

7
8

5

6

2

4

SDP

SDN

RDP

RDN

TRE

P24G

7
8

5

6

2

4

7
8

5

6

2

4

SDP

SDN

RDP

RDN

TRE

SDP

SDN

RDP

RDN

TRE

(Note1)

Axis 32 (last axis)

servo amplifier

CNP1 connector

P24G

P24G

Note: 1. Molex's CNP1 connector

Connector: 5557-08R

2. In the last axis, connect TRE and RDN.