2 write commands, Communication functions – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 167

Advertising
background image

13 - 11

13. COMMUNICATION FUNCTIONS

(5) Current alarm (Command [0][2]

[3][5])

Command

Data No.

Description

Frame Length

[0][2]

[0][0]

Current alarm number

4

Command

Data No.

Description

Display Item

Frame Length

[3][5]

[8][0]

cumulative feedback pulses

12

[3][5]

[8][1]

servo motor speed

12

[3][5]

[8][2]

droop pulses

12

[3][5]

[8][3]

cumulative command pulses

12

[3][5]

[8][4]

command pulse frequency

12

[3][5]

[8][5]

analog speed command voltage
analog speed limit voltage

12

[3][5]

[8][6]

analog torque command voltage
analog torque limit voltage

12

[3][5]

[8][7]

regenerative load ratio

12

[3][5]

[8][8]

effective load ratio

12

[3][5]

[8][9]

peak load ratio

12

[3][5]

[8][A]

within one-revolution position

12

[3][5]

[8][B]

Multi-revolution counter

12

[3][5]

[8][C]

Status display data value and
processing information at alarm
occurrence

load inertia moment ratio

12

(6) Others

Command

Data No.

Description

Frame Length

[0][2]

[9][0]

Servo motor end pulse unit absolute position

8

[0][2]

[9][1]

Command unit absolute position

8

[0][2]

[7][0]

Software version

16

13.11.2 Write commands

(1) Status display (Command [8][1])

Command

Data No.

Description

Setting Range

Frame Length

[8][1]

[0][0]

Status display data clear

1EA5

4

(2) Parameter (Command [8][4])

Command

Data No.

Description

Setting Range

Frame Length

[8][4]

[0][0] to

[3][1]

Each parameter write
(The decimal equivalent of the data No. value
(hexadecimal) corresponds to the parameter
number.)

Depends on the
parameter.

8

(3) Alarm history (Command [8][2])

Command

Data No.

Description

Setting Range

Frame Length

[8][2]

[2][0]

Alarm history clear

1EA5

4

(4) Current alarm (Command [8][2])

Command

Data No.

Description

Setting Range

Frame Length

[8][2]

[0][0]

Alarm reset

1EA5

4

Advertising