2 installation direction and clearances, Installation, Caution – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 23

Advertising
background image

2 - 2

2. INSTALLATION

2.2 Installation direction and clearances

CAUTION

y The equipment must be installed in the specified direction. Otherwise, a fault may

occur.

y Leave specified clearances between the servo amplifier and control box inside walls

or other equipment.

(1) Installation of one servo amplifier

70mm
(2.8 in.)

MITSUBISHI

OPEN

CN1A

CN1B

CNP1

CNP2

CNP3

MELSERVO

10mm
(0.4 in.)
or more

40mm
(1.6 in.)
or more

10mm
(0.4 in.)
or more

40mm
(1.6 in.)
or more

Top

Bottom

Wiring clearance

Control box

Control box

Servo amplifier

(2) Installation of two or more servo amplifiers

Leave a large clearance between the top of the servo amplifier and the internal surface of the control

box, and install a fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.

Control box

100mm
(4.0 in.)
or more

10mm
(0.4 in.)
or more

1mm
(0.04 in.)
or more

MITSUBISHI

OPEN

CN1A

CN1B

CNP1

CNP2

CNP3

MELSERVO

MITSUBISHI

OPEN

CN1A

CN1B

CNP1

CNP2

CNP3

MELSERVO

10mm
(0.4 in.)
or more

40mm
(1.6 in.)
or more

(3) Others

Install the servo amplifier on a perpendicular wall in the correct vertical direction.