3. SIGNALS AND WIRING

3. SIGNALS AND WIRING

WARNING

y Any person who is involved in wiring should be fully competent to do the work.
y Before starting wiring, make sure that the voltage is safe in the tester more than 10

minutes after power-off. Otherwise, you may get an electric shock.

y Ground the servo amplifier and the servo motor securely.
y Do not attempt to wire the servo amplifier and servo motor until they have been

installed. Otherwise, you may get an electric shock.

y The cables should not be damaged, stressed excessively, loaded heavily, or

pinched. Otherwise, you may get an electric shock.

CAUTION

y Wire the equipment correctly and securely. Otherwise, the servo motor may

misoperate, resulting in injury.

y Connect cables to correct terminals to prevent a burst, fault, etc.
y Ensure that polarity (+,

) is correct. Otherwise, a burst, damage, etc. may occur.

y The surge absorbing diode installed to the DC relay designed for control output

should be fitted in the specified direction. Otherwise, the signal is not output due to

a fault, disabling the forced stop and other protective circuits.

Control output
signal

COM

(24VDC)

Servo amplifier

RA

y Use a noise filter, etc. to minimize the influence of electromagnetic interference,

which may be given to electronic equipment used near the servo amplifier.

y Do not install a power capacitor, surge suppressor or radio noise filter with the power

line of the servo motor.

y Do not modify the equipment.

POINT

CN1A and CN1B have the same shape. Wrong connection of the connectors
will lead to a failure. Connect them correctly.