2 signal explanations, Signals and wiring – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 35

Advertising
background image

3 - 10

3. SIGNALS AND WIRING

3.3.2

Signal explanations

For the I/O interfaces (symbols in I/O column in the table), refer to Section 3.6.2.
In the Control Mode field of the table
P : Position control mode, S: Speed control mode, T: Torque control mode
{

: Denotes that the signal may be used in the initial setting status.

: Denotes that the signal may be used by setting the corresponding parameter among parameters 43 to

49.

(1) Input signals

Control

Mode

Signal

Symbol

Connec-

tor Pin

No.

Functions/Applications

I/O

Division

P

S

T

Servo-on

SON

CN1B

5

Ready signal input terminal.
Connect SON-SG to switch on the base circuit and make the servo
amplifier ready to operate (servo on).
Disconnect SON-SG to shut off the base circuit and coast the
servo motor (servo off) .
Set†††1 in parameter No. 41 to switch this signal on
(keep terminals connected) automatically in the servo
amplifier.

DI-1

{ { {

Reset

RES

CN1B

14

Alarm reset signal input terminal.
Disconnect RES-SG for more than 50ms to reset the alarm.
Some alarms cannot be deactivated by the reset signal. Refer to
Section 9.2.
The base circuit is shut off while RES-SG are shorted.

DI-1

{ { {

Forward/reverse rotation stroke end signal input terminals.
To start operation, short LSP-SG and/or LSN-SG. Open them to
bring the motor to a sudden stop and make it servo-locked.
Set†††1 in parameter No. 22 to make a slow stop.

(Note) Input signals

Operation

LSP

LSN

CCW

direction

CW

direction

1

1

{

{

Forward rotation
stroke end

LSP

CN1B

16

0

1

{

1

0

{

0

0

Note. 0: OFF (LSP/LSN-SG open)

1: ON (LSP/LSN-SG shorted)

Set parameter No. 41 as indicated below to switch on the signals
(keep terminals connected) automatically in the servo amplifier:

Parameter No.41

Automatic ON

††

LSP

†

1††

LSN

Reverse rotation
stroke end

LSN

CN1B

17

DI-1

{ {