5 alarm occurrence timing chart, Signals and wiring, Caution – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 59

Advertising
background image

3 - 34

3. SIGNALS AND WIRING

3.5 Alarm Occurrence Timing Chart

CAUTION

y When an alarm has occurred, remove its cause, make sure that the operation

signal is not being input, ensure safety, and reset the alarm before restarting

operation.

When an alarm occurs in the servo amplifier, the base circuit is shut off and the servo motor is coated to a
stop. Switch off the main circuit power supply in the external sequence. To reset the alarm, switch the
control circuit power supply off, then on.
However, the alarm cannot be reset unless its cause of occurrence is removed.

ON

OFF

power supply

ON

OFF

Base circuit

Dynamic brake

Valid

Invalid

ON

OFF

Servo on
(SON)

ON

OFF

Reset
(RES)

ON

OFF

Ready
(RD)

ON

OFF

Trouble
(ALM)

1s

Alarm occurs.

Remove cause of trouble.

Brake operation

Brake operation

Power off

Power on

Instantaneous power fallure alarm

50ms or

more

15ms or more

Precautions for alarm occurrence

1) Overcurrent, overload 1 or overload 2

If operation is repeated by switching control circuit power off, then on to reset the overcurrent (A.
32), overload 1 (A. 50) or overload 2 (A. 51) alarm after its occurrence, without removing its cause,
the servo amplifier and servo motor may become faulty due to temperature rise. Securely remove
the cause of the alarm and also allow about 15 minutes for cooling before resuming operation.

2) Instantaneous power failure

If a power failure continues 15ms or longer, the undervoltage (A. 10) alarm will occur. If the
power failure still persists for 20ms or longer, the control circuit is switched off. When the power
failure is reset in this state, the alarm is reset and the servo motor will start suddenly if the
servo-on signal (SON) is on. To prevent hazard, make up a sequence which will switch off the
servo-on signal (SON) if an alarm occurs.

3) Position control mode

When an alarm occurs, the home position is lost. When resuming operation after deactivating the
alarm, make a return to home position.