8 servo motor with electromagnetic brake, Signals and wiring – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 68

Advertising
background image

3 - 43

3. SIGNALS AND WIRING

3.8 Servo Motor with Electromagnetic Brake

(1) Setting

Using parameter No.33 (electromagnetic brake sequence output), set a time delay from electromagnetic
brake operation to base circuit shut-off as in the timing chart shown in (2) in this section.

(2) Operation timing

(a) Servo on signal command (from controller) ON/OFF

Tb after the servo-on signal is switched off, the base circuit is shut off and the servo motor coasts.
The following chart shows the way of holding the motor shaft in vertical lift applications.

Adjust Tb (parameter No. 33) to minimize a drop after the servo-on signal is switched off.
Switch off the servo-on signal after the servo motor has stopped.

Servo motor speed

Electromagnetic

brake (CNP2-9)

ON

OFF

Base circuit

Invalid(ON)

Valid(OFF)

ON

OFF

Servo-on(SON)

Electromagnetic brake
operation delay time(10ms)

Tb

Coasting

0 r/min

(60ms)

(80ms)

(b) Emergency stop signal (EMG) ON/OFF

Electromagnetic brake
operation delay time
(10ms)

Dynamic brake

Dynamic brake
Electromagnetic brake

Servo motor speed

Electromagnetic
brake(CNP2-9)

ON

OFF

Base circuit

Invalid(ON)

Valid(OFF)

Invalid(ON)

Valid(OFF)

Electromagnetic
brake

Electromagnetic brake release

Forced stop(EMG)

(180ms)

(180ms)

Advertising