3. SIGNALS AND WIRING

3.9 Grounding

WARNING

y Ground the servo amplifier and servo motor securely.
y To prevent an electric shock, always connect the earth terminal (E) of the servo

amplifier to the earth (E) of the control box (refer to (2) of this section for the fitting

method of the earth terminal).

(1) Connection diagram

The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending
on the wiring and ground cablerouting, the servo amplifier may be affected by the switching noise (due
to di/dt and dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always
ground.
To conform to the EMC Directive, refer to the EMC INSTALLATION GUIDELINES (IB(NA)67310).

P24M

P24G

P24L

Servo motor

CN1A CN1B

Earth (E)

24VDC

Circuit

protector

Control box

Servo amplifier

Outer
box

P

rogram

m

abl

e

cont

rol

le

r

RA