6 - 1

6. DISPLAY AND OPERATION

6. DISPLAY AND OPERATION

6.1 Display Flowchart

Use the display (4-digit, 7-segment LED) on the front panel of the servo amplifier for status display,
parameter setting, etc. Set the parameters before operation, diagnose an alarm, confirm external
sequences, and/or confirm the operation status. Press the "MODE" "UP" or "DOWN" button once to move
to the next screen.
To refer to or set the expansion parameters, make them valid with parameter No. 19 (parameter write
disable).

Status display

Cumulative feedback

pulses [pulse]

Motor speed

[r/min]

Droop pulses
[pulse]

Cumulative command

pulses [pulse]

Command pulse

frequency [kpps]

Speed command voltage

Speed limit voltage[mV]

Torque limit voltage

Torque command voltage[mV]

Regenerative load

ratio [%]

Effective load ratio

[%]

Peak load ratio

[%]

Within one-revolution

position [pulse]

Multi-revolution
counter [rev]

Load inertia moment

ratio [times]

Diagnosis

Sequence

External I/O
signal display

Output signal
forced output

Test operation
Jog feed

Test operation
Positioning operation

Test operation
Motor-less operation

Software
version L

Software
version H

Automatic VC
offset

Current alarm

Last alarm

Second alarm
in past

Third alarm
in past

Fourth alarm
in past

Fifth alarm
in past

Sixth alarm
in past

Parameter
error No.

Basic parameters

Parameter No. 0

Parameter No. 1

Parameter No. 18

Parameter No. 19

Expansion
parameters

Parameter No. 20

Parameter No. 21

Parameter No. 48

Parameter No. 49

MODE

UP

DOWN

Alarm

(Note)

(Note)

(Note)

button

Note: The initial status display at power-on depends on the control mode.

Positon control mode: Cumulative feedback pulses(C), Speed control mode: Motor speed(r),
Torque control mode: Torque command voltage(U)