CLI – This example sets the 802.1X parameters on port 2. For a
description of the additional fields displayed in this example, see “show
dot1x” on page 4-114.

Console(config)#interface ethernet 1/2

4-145

Console(config-if)#dot1x port-control auto

4-109

Console(config-if)#dot1x re-authentication

4-111

Console(config-if)#dot1x max-req 5

4-109

Console(config-if)#dot1x timeout quiet-period 30

4-112

Console(config-if)#dot1x timeout re-authperiod 1800

4-112

Console(config-if)#dot1x timeout tx-period 40

4-113

Console(config-if)#end
Console#show dot1x

4-114

Global 802.1X Parameters
system-auth-control: enable

802.1X Port Summary
Port Name Status Operation Mode Mode Authorized
1/1 disabled Single-Host ForceAuthorized n/a
1/2 enabled Single-Host auto yes

.

.

.
1/52 disabled Single-Host ForceAuthorized n/a

802.1X Port Details
802.1X is disabled on port 1/1

802.1X is enabled on port 1/2
reauth-enabled: Enable
reauth-period: 1800
quiet-period: 30
tx-period: 40
supplicant-timeout: 30
server-timeout: 10
reauth-max: 2
max-req: 5
Status Authorized
Operation mode Single-Host
Max count 5
Port-control Auto
Supplicant 00-00-e8-49-5e-dc
Current Identifier 3
Authenticator State Machine
State Authenticated
Reauth Count 0

Backend State Machine
State Idle
Request Count 0
Identifier(Server) 2

Reauthentication State Machine
State Initialize

.

.

.

802.1X is disabled on port 1/52
Console#