Table 007-3 – NEC NEAX2000 IVS ND-45492 User Manual

Page 115

Advertising
background image

CHAPTER 3

ND-45492 (E)

Page 98
Revision 2.0

* Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.

NAP 200-007

Sheet 13/56

Termination of Cables on the MDF

Table 007-3 LTC0-LTC2 MDF Cross Connection Information (2 of 4)

PIN

RUNNING

CABLE

STATION

CABLE

SLOTS

TYPE OF INTERFACE

COT

(4COT)

COT

(2COT)

2-WIRE

E&M TIE

LINE

(2ODT)

4-WIRE

E&M TIE

LINE

(2ODT)

DID

(AUC)

SLT

(4LC)

SLT

(AUC)

38

BK-GN

GN

4

T0

T0

T0

TxT0

T0

T0

T0

13

GN-BK

RD

R0

R0

R0

TxR0

R0

R0

R0

39

BK-BR

BK

T1

T1

T1

RcvT0

T1

T1

T1

14

BR-BK

YL

R1

R1

R1

RcvR0

R1

R1

R1

40

BK-SL

GN

T2

T2

TxT1

T2

15

SL-BK

RD

R2

R2

TxR1

R2

41

YL-BL

BK

T3

T3

RcvT1

T3

16

BL-YL

YL

R3

R3

RcvR1

R3

42

YL-OR

GN

5

T0

T0

T0

TxT0

T0

T0

T0

17

OR-YL

RD

R0

R0

R0

TxR0

R0

R0

R0

43

YL-GN

BK

T1

T1

T1

RcvT0

T1

T1

T1

18

GN-YL

YL

R1

R1

R1

RcvR0

R1

R1

R1

44

YL-BR

GN

T2

T2

TxT1

T2

19

BR-YL

RD

R2

R2

TxR1

R2

45

YL-SL

BK

T3

T3

RcvT1

T3

20

SL-YL

YL

R3

R3

RcvR1

R3

46

VI-BL

GN

6

T0

T0

T0

TxT0

T0

T0

T0

21

BL-VI

RD

R0

R0

R0

TxR0

R0

R0

R0

47

VI-OR

BK

T1

T1

T1

RcvT0

T1

T1

T1

22

OR-VI

YL

R1

R1

R1

RcvR0

R1

R1

R1

48

VI-GN

GN

T2

T2

TxT1

T2

23

GN-VI

RD

R2

R2

TxR1

R2

49

VI-BR

BK

T3

T3

RcvT1

T3

24

BR-VI

YL

R3

R3

RcvR1

R3

50

VI-SL

MN *

25

SL-VI

MJ *

Advertising