Figure 003-9, Cable connection on the pz-pw86 (continued) – NEC NEAX2000 IVS ND-45492 User Manual

Page 49

Advertising
background image

CHAPTER 3

ND-45492 (E)

Page 32

Addendum-001

Revision 2.1

JANUARY, 1999

(b) PZ-PW86 (C)

Figure 003-9 Cable Connection on the PZ-PW86 (2 of 3)

NAP 200-003

Sheet 10/37

Installation of Main Equipment

PZ-PW86(C)

MJ

MN

ON

BATTERY MODE SWITCH

GND Note 2
FG

–27V

PWR CNT CA-A

PWR CA-A

BATTERY CABLE/PWR CA-A

TO PWR1

TO OTHER

AC CORD-A

TO AC MAINS INPUT

TO

POWER OUTPUT

POWER OUTPUT

TO PWR0A CONNECTOR
TO PWR0B CONNECTOR

CABLE (+5V, –27V,E)

CABLE (CR, E)

CONNECTOR

PZ-PW86

TO AUXILIARY

BATTERY CONNECTOR (BATT2)

ON

OFF

100/120V

240V

EQUIPMENT

TO BATTERY OR
OTHER PZ-PW86

GREEN

WHITE

BLACK

AC CORD-B

OR

(FOR 1-PIM SYSTEMS)

TO THE TERMINAL BLOCK AT BASE
(FOR MULTIPLE PIM SYSTEMS)

FRAME GROUND TERMINAL ON THE CHASSIS

Set the appropriate voltage before turning on
the SW switch.

CAUTION

Note 1:

Follow the Label on Front Plate of the PZ-
PW86(C).

Note 2:

If GND (Signal GND) has to be separated from
FG (Frame GND), remove the link between
GND and FG terminals.

1: NO CONNECTION

OFF: OPEN/FLOAT 1

2: ON: SEAL/FLOAT 2

O

BATTERY CONNECTOR (BATT1)

1
2

ON

(FOR 1-PIM SYSTEMS)

L

N

NOMINAL

AC INPUT

TO TERMINAL

MARKED:

ON BASE

(See

Figure 003-11

)

Note 1

TO PWR0D CONNECTOR

POWER OUTPUT CABLE (+90V,E)

Advertising