3. Starting Up the Back up MP System

To start up the Back up MP system, do the following steps. For details of switch settings on the MP card (PN-
CP02), refer to the Circuit Card Manual.

STEP 1:

After serial numbers (Compact and Advantage) have been loaded, see

Note 1

.

make Busy Side 0 SW 4 in the UP position.
Side 1 (MP1) SW4 is in the DOWN position.

STEP 2:

Turn on the SW switch on the PZ-PW86.

STEP 3:

The Run lamp on the MP1 card flashes at 120IPM. Turn SW3 on the MP1 card to B reset (push) SW1;
wait for the minor Alarm.
Turn SW3 to 0 (on line). Reset SW1. Turn SW3 to C, reset SW1, wait for minor alarm, then turn SW1
back to 0 (on line). Reset SW1

STEP 4:

Make Busy SW 4 (UP position) on the MP1. On side 0 (MP0) put SW4 in the DOWN position. Reset
SW1 when MP0 run LED is flashing 120IPM.

STEP 5:

Repeat Step 3 for side 0 (MP0).

STEP 6:

Enter the data required for Back up MP System from the CAT/MAT.

CM40 (Attribute data assignment for RS-232C port)

YY = 01 (Data length)

1st data: 0 (Port 0)

2nd data: 1 (8 bits)

YY = 02 (Parity check)

1st data: 0 (Port 0)

2nd data: 1 (Ineffective)

YY = 04 (Stop bit)

1st data: 0 (Port 0)

2nd data: 1 (2 bits)

YY = 05 (DTR signal)

1st data: 0 (Port 0)

2nd data: 1 (High)

YY = 06 (RTS signal)

1st data: 0 (Port 0)

2nd data: 1 (High)

YY = 08 (Data speed)

1st data: 0 (Port 0)

2nd data: 4 (9600 bps)

YY = 09 (Port for data load/save/verify) 1st data: 1

2nd data: 1 (Port 0)

In addition to the above mentioned data, set the following data, if it is necessary.

CMEA Y = 2 1st data: 01 (Registration into the Fault Information Memory and external alarm kind
of System Initialization)
2nd data : 0 (Fault information is registered, external alarm is not output)

: 1 (Fault information is registered, external alarm is MN alarm)
: 2 (Fault information is registered, external alarm is MJ alarm)
: 3 (Fault information is registered, external alarm is determined in standard data

<Refer to the Command Manual for details>)

: NONE (Fault information is not registered, external alarm is not output)

NAP 200-009

Sheet 4/6

Installation of Back up MP System