NEC NEAX2000 IVS ND-45492 User Manual

Page 166

Advertising
background image

ND-45492 (E)

CHAPTER 3

Page 149

Revision 2.0

STEP 7:

On side 1 (MP1) place SW4 in the DOWN position.
Ensure that SW2 1-8 are OFF and Side 0 (MP0)SW2-8 is ON.
Start programming Office Data from either the CAT or MAT.

STEP 8:

When Office Data is completed, set SW2-8 OFF on Side 0 (MP0) and on side 1 (MP1) Reset (push)
SW1. The run LED on side 1 (MP1) will light solid. After about 5 minutes, the run LED on the MP1
will flash (3 seconds on, 1 second off). The system data stored in the MP0 card is copied to the MP1
card.
After about 30 minutes, the Run LED lamp flashing pattern on side 1 (MP1) is changed to 1 second on,
1 second off.
The MP1 card starts up as the stand-by MP.

Note 1:

The Compact serial number, Advantage serial number, CPN serial number and System CPU ID code must
be loaded separately on each MP.

For example:

MP0

MP1

CPU # 0123456789101

CPU # 9876543210000

Compact # 0123456789

Compact # 9876543210

Advantage # 0123456789

Advantage # 9876543210

IVR ID # 0123456789

IVR ID # 9876543210

NAP 200-009

Sheet 5/6

Installation of Back up MP System