CHAPTER 3

ND-45492 (E)

Page 72

Addendum-001

Revision 2.1

JANUARY, 1999

1. Battery Connection

WARNING:

Turn off AC power before connecting batteries.

NAP 200-005

Sheet 1/7

Connection of Battery

Recommended Battery

Internal Battery:

YUASA
MATSUSHITA

type NPH-3.2-12
type LCR-12V3.4NE

External Battery:
(BATTM)

YUASA
MATSUSHITA

type NP-24-12B
type LCL-12V-24

If battery terminals (+, –) contact with the module while connecting the battery cable to the PZ-PW86 card,
the PZ-PW86 card or the BWB may be shorted. Therefore, the installer must perform work in accordance with
the following steps when mounting or removing the batteries.

(1) When mounting batteries:

(a)

Connect the battery cable to the batteries.

(b)

Mount the batteries into the appointed position of the PIM or the BATTM.

(c)

Connect the battery cable to the PZ-PW86 card.

(2) When removing batteries:

(a)

Disconnect the battery cable from the PZ-PW86 card.

(b)

Remove the batteries from the PIM or the BATTM.

CAUTION