1.2. Battery Connection in the BATTM

(1) Connect the battery cables to the batteries, and mount the battery units (24 V DC, 24AH per unit) into the

Battery Module (BATTM) as shown in

Figure 005-4

.

Figure 005-4 Battery Mounting into the BATTM

NAP 200-005

Sheet 6/7

Connection of Battery

+

+

+

+

BATTERY CABLE

TO PZ-PW86 IN PIM0/PIM4

BATTM

BATTERY UNIT (24 V DC, 24AH)

BATTERY UNIT (24 V DC, 24AH)

FRONT

TO PZ-PW86 IN PIM0/PIM4

Recommended Batteries

Yuasa NP-24-12B
Matsushita LCL-12V-24

Specifications

UL Listed
12VDC, 24AH
Terminal: bolt/nut type with hole for 5mm bolt
Dimensions:

166mm L x 175mm W x 125mm H
(6.54in L x 6.89in W x 4.92in H)

A: 12mm

5.5mm

B: 2mm

(.216in)

(.472in)

(.079in)