2. Cable Running to the External MDF

(1) When not using the cable hole of the PIM

(a) Bring the MDF cable up to the Main Equipment through the cable hole(s) of the BASE.

(b) Connect the champ connector of each MDF cable to an LTC connector located on a PIM using the

screws provided, as shown in

Figure 006-2

.

(c) Pare the sheath of each MDF cable and secure the shield to the front bracket on the PIM using tie

wraps, as shown in

Figure 006-2

.

Figure 006-2 Cable Running to the External MDF (1 of 2)

NAP 200-006

Sheet 3/7

Cable Running to the MDF

LTC CONNECTOR

CHAMP CONNECTOR

FRONT

TO MDF

BASE

PIM0

PIM1

PBX

TIE WRAP

SHIELD

PIM

MDF CABLE

25 ~ 30 mm
(1.0 ~ 1.2 inch)