ASMi-52 Ver. 2.5

Configuring ASMi-52

1

Quick Start Guide

Installation of ASMi-52 should be carried out only by an experienced technician. If
you are familiar with ASMi-52, use this guide to prepare the units for operation.

1. Installing

ASMi-52

Connecting the Interfaces

1. Connect the line to the RJ-45 rear panel connector dedicated SHDSL.
2. Connect the DTE to the appropriate rear panel connector.
3. Connect the control terminal to the rear panel CONTROL connector.

Connecting the Power

• Connect the AC or DC power to the ASMi-52 modem.

The unit has no power switch. Operation starts when power is connected
to the rear panel power connector.

2. Configuring

ASMi-52

Configure ASMi-52 to the required operation mode via an ASCII terminal
connected to the rear panel CONTROL port directly or via a modem link.

Connecting the Terminal

To connect the terminal:
1. Connect the terminal cable to the CONTROL connector of ASMi-52.
2. Turn the control terminal on.
3. Configure the terminal to the default communication parameters: 9.6 kbps,

one start bit, eight data bits, no parity, one stop bit.

4. Select the full-duplex mode.
5. Turn the terminal echo off.
6. Disable any type of flow control.

You are now ready to start a control session.