Configuring the t1 interface, Configuring the 10/100baset interface – RAD Data comm ASMi-52 User Manual

Page 13

Advertising
background image

Installation and Operation Manual

Quick Start Guide

ASMi-52 Ver. 2.5

Configuring ASMi-52

3

To configure E1 parameters:
• From the E1 Port Configuration menu (Main Menu > Configuration > Port

Configuration > E1 Port Configuration), configure the following E1
parameters:

Framing mode

Timeslot assignment

You can configure timeslot 0 to be looped or transparent:

Looped – timeslot 0 is sent back to the E1 interface, when operating
opposite remote units with a serial data interface.

Transparent – timeslot 0 is transmitted to the remote modem.

If you operate ASMi-52 with the G732S framing, timeslot 0 is always

transparent and timeslot 16 is always connected.

When operating a 2-wire ASMi-52 with E1 interface opposite ASMi-52 with

V.35 interface (not in LS mode), assign at least three timeslots, excluding
timeslot 0, to carry data.

When operating a 4-wire ASMi-52 with E1 interface opposite ASMi-52 with

V.35 interface (not in LS mode), assign at least six timeslots, excluding timeslot
0, to carry data.

Configuring the T1 Interface

To configure the T1 parameters:
• From the T1 Port Configuration menu (Main Menu > Configuration > Port

Configuration > T1 Port Configuration), configure the following T1 parameters:

Framing mode

Line coding

Receive gain

Interface type

Transmit signal mask

Timeslot assignment

Configuring the 10/100BaseT Interface

To configure 10/100BaseT parameters:
• From the LAN Configuration menu (Main Menu > Configuration > System

Configuration > LAN Configuration), configure the following LAN parameters:

Bridge static table

Aging timeout

LAN rate

Note