Site Requirements and Prerequisites

2-1

Chapter 2
Installation and Setup

2.1 Introduction

This chapter describes installation and setup procedures for the standalone
ASMi-52 modem.
After installing the unit:
• Refer to

Chapter 3

for the operating instructions.

• Refer to

Chapter 4

for the detailed system configuration procedures using an

ASCII terminal connected to the ASMi-52 control port.

If a problem is encountered, refer to

Chapter 5

for test and diagnostic instructions.

Internal settings, adjustment, maintenance, and repairs may be performed
only by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.

The ASMi-52 standalone unit is designed for desktop or bench installation and is
delivered as a fully assembled unit. No provisions are made for bolting the unit to
a tabletop.

To install ASMi-52:
1. Determine the required configuration of ASMi-52, in accordance with your

application.

2. Connect the line (see

Connecting the Line

below).

3. Connect the DTE (see

Connecting the DTE Interface

below).

4. Connect power to the unit (see

Connecting the Power

below).

2.2 Site Requirements and Prerequisites

AC-powered ASMi-52 units should be installed within 1.5m (5 ft) of an

easily-accessible grounded AC outlet capable of furnishing the voltage in
accordance with ASMi-52 nominal supply voltage.
DC-powered ASMi-52 units require a -48 VDC power source, which must be
adequately isolated from the main supply.