Bit error rate test (bert), Bert patterns – RAD Data comm ASMi-52 User Manual

Page 121

Advertising
background image

Installation and Operation Manual

Chapter 6 Troubleshooting and Diagnostics

ASMi-52 Ver. 2.5

Testing ASMi-52

6-17

Bit Error Rate Test (BERT)

It is possible to generate BERT+RLB or BERT (from both CO and CPE) in
multiplexer and E1 and DTE Serial single units.
The BERT, RLB + BERT can be set only if there is a connection to the FE unit.

BERT Patterns

The following are the BERT test patterns that can be selected:
• 2E15-1
• Mark
• Space
• Alternate

BERT has a possible Single Error injection only.
The BERT performance counters are as follows:
• Error bits – the total number of bit errors detected
• BERT total time – the total time the test is running in seconds
• Bert error time – the total number of seconds in which errors have been

detected – in seconds

• BERT Sync Loss – the number of times Sync Loss was detected since BERT

started to run

• BERT result – the number of error bits divided with the total number of data

bits. This item holds 1 byte for the exponent and 2 bytes for the mantissa
holding 1 byte before the period and 1 byte after the period

• BERT Sync Loss state – the Sync Status while BERT runs. The BERT Sync Loss

state has the following values:

SyncLoss = 0

Sync = 1

• BERT sync run time – the total number of seconds in which sync have been

detected – in seconds

• BERT total bits – the total number of bert bit.

To select the BERT patterns values for Local and Remote tests:
1. From the Diagnostics menu, select Local/Remote Test (Main menu >

Monitoring > Local/Remote Test).

The Local/Remote Test menu is displayed (see

Figure 6-23

).

2. From the Local/Remote Test menu, select BERT.

The BERT menu is displayed.