Masking port alarms – RAD Data comm ASMi-52 User Manual

Page 115

Advertising
background image

Installation and Operation Manual

Chapter 6 Troubleshooting and Diagnostics

ASMi-52 Ver. 2.5

Handling Alarms

6-11

ASMi-52

Physical port status

Port Number

(1)

1. Port status

2. Line mask

(NO_MASK)

3. Port log file

4. Port clear log file

>

ESC-prev. menu; !-main menu; &-exit; @-scroll

Figure 6-14. Physical Port Status Menu

Masking Port Alarms

ASMi-52 allows you to mask alarms generated by local and remote devices.

To mask ASMi-52 alarms:
• From the Physical Port Status menu (

Figure 6-14

), select Line mask (Main

menu > Monitoring > Physical Port Status > Line Mask).

The Line Mask value changes to Mask. ASMi-52 starts ignoring all alarms
generated devices connected to the modem.

Table 6-3. ASMi-52 Alarms and Warnings

Number Terminal

Message

Port

Description

Severity

1

SELF TEST ERROR

Failure occurred during self-test

Major

2 SOFTWARE

DOWNLOAD

Software download is in progress

Warning

4

LLB FROM DTE

DTE

Local loopback has been activated by a physical

connector (units with V.35 DTE interface only)

Warning

5

RLB FROM DTE

DTE

Remote loopback has been activated by a

physical connector (units with V.35 DTE interface

only)

Warning

6

PROP PROT FAIL

SHDSL

FE Management by EOC failed

Warning

8 LAN

NOT

CONNECTED

DTE

The Ethernet interface is not connected to the

LAN

Major

9 LOOP

ATTN.

OVER

LINE A

SHDSL

Line A loop attenuation has exceeded the alarm

threshold

Minor

10 LOOP

ATTN.

OVER

LINE B

SHDSL

Line B loop attenuation has exceeded the alarm

threshold (4-wire units only)

Minor

11

SNR MARGIN OVER

LINE A

SHDSL

Line A signal-to-noise margin has exceeded the

alarm threshold

Minor

Advertising