Chapter 6 Troubleshooting and Diagnostics

ASMi-52 Ver. 2.5

Handling Alarms

6-13

Table 6-3. ASMi-52 Alarms and Warnings (Cont.)

Number Terminal

Message

Port

Description

Severity

32

E1 EXCESIVE ERR

RATIO
T1 EXCESIVE ERR

RATIO

DTE

The bit error rate of the link exceeds 10

-3

Major

33

E1 AIS OCCURED
T1 AIS OCCURED

DTE

AIS is detected at the E1 or T1 port

Major

34

E1 AIS AND SYNC
LOSS
T1 AIS AND SYNC

LOSS

DTE

AIS and loss of frame alignment are detected at
the E1 or T1 port

Major

35 E1

SYNC

LOSS

T1 SYNC LOSS

DTE

E1 or T1 loss of frame synchronization occurred

Major

36

E1 CRC MF EXC

DTE

CRC errors detected in the frame synchronization

signal exceeded the threshold

Minor

37

E1 REMOTE SYNC

LOSS
T1 REMOTE SYNC
LOSS

DTE

Remote loss of frame synchronization occurred

Major

38

E1 MF SYNC LOSS

DTE

Local loss of frame synchronization

Major

39

E1 MF REMOTE SYNC

LOSS

DTE

Remote loss of frame synchronization

Major

40

E1 TS NOT X128
T1 TS NOT X128

DTE

Number of timeslots assigned for the ASMi-52
unit with 4-wire line interface is not n×128

Major

41

E1 TS NOT COMP
T1 TS NOT COMP

DTE

Number of timeslots assigned for the local unit

does not match the number of timeslots assigned

for the remote unit.

Major

42 WIRE

MODE

NOT

COMP

SHDSL

Mismatch between line interface types (2/4-wire)

between local and remote units

Major

43

SPAN IS NOT FULL

SHDSL

The distance between adjacent repeaters is too

long. You can identify the problematic segment

by checking the Port Status screen. In the
Number of Repeaters line, it displays the last

repeater identified by ASMi-52. This means that

the distance between the last detected repeater
and the next repeater exceeds its maximum

range.

Major

44 LOOP

ATTN.

OVER

NETWORK SIDE

SHDSL

Loop attenuation at the network side of the

repeater has exceeded the alarm threshold

Major

Advertising