Displaying the port status – RAD Data comm ASMi-52 User Manual

Page 87

Advertising
background image

Installation and Operation Manual

Chapter 4 Configuration

ASMi-52 Ver. 2.5

Additional Tasks

4-37

ASMi-52

System Status
Local

Remote

Device Type

(ASMi52_SA_M (PLASTIC)-STU_C-2W)

ASMi52_SA

Clock Source

(INT)

RCV

Software Version (2.01E24)

(2.01E24)

Hardware Version (0.00)

(0.00)

FPGA Version

(0.13)

(0.13)

Hardware Status

(NO HARDWARE FAILURE)

(NO HW

FAILURE)

PS

(WIDE RANGE PS 48-60 VDC/100-240 VAC)

(WIDE

RANGE)

MAC address

(0 20 D2 20 5F AB)

(0 20 D2 21

12)

IP address

(172.17.161.73)

(172.17.161.75)

Alarm Indication NORMAL

NORMAL

Test Indication

(OFF)

(OFF)

>

ESC-prev. menu; !-main menu; &-exit;

Figure 4-39. System Status Screen

Alarms are described in

Chapter 5

.

Displaying the Port Status

To display the port status information:
1. From the Physical Port Status menu, select Port Status (Main menu >

Monitoring > Physical Port Status > Port Status) to display the port status.

The Port Status menu appears (see

Figure 4-40

).

ASMi-52

Port status
Local

Remote

SHDSL

(Standard ANNEX_B, Wire mode 2W)

______

SHDSL Line

(Status: SYNC, State: DATA mode)

______

Framer Type

(SLOTTED E1)

______

EOC compatible

(PROPRIETARY)

______

Actual PSD

(ASYM_PSD_DISABLE)

______

Line rate

(2048 kbps + 8 kbps)

______

E1 interface

(IR-G704-E1/BALANCE Data rate: 2048 kbps) ______

HW status

(NO HARDWARE FAILURE)

______

Test status

(NONE)>

______

Alarm status

(NORMAL)

______

REM connected line (1)

______

(N)


ESC-prev. menu; !-main menu; &-exit;

Figure 4-40. Port Status Menu