RAD Data comm ASMi-52 User Manual

Page 110

Advertising
background image

Chapter 6 Troubleshooting and Diagnostics

Installation and Operation Manual

6-6 Monitoring

Performance

ASMi-52 Ver. 2.5

ASMi-52

E1/T1 current day performance

Local

Remote

Port number (1)

No statistics collection

ESC-prev. menu; !-main menu; &-exit; @-scroll

Figure 6-9. E1/T1 Current Day Performances Screen

Table 6-2. E1/T1 Statistics Parameters

Range

Display Description

15 min

24 hour

CRC errors

Number of CRC error events recorded since the last time the register was

cleared.

– –

CRC avrg

errors

The average number of CRC events per second. This value is updated

every second.

– –

Current ES

Number of errored seconds in which one or more CRC (Cyclic

Redundancy Check) error events occurred during the current interval. This
value is updated every second for 15-minute interval or every 15 minute

for 24-hour interval.

0–900 0–65535

Current SES

Number of severely errored seconds in which 832 or more CRC error

events occurred during the current interval. This value is updated every

second for 15-minute interval or every a 15 min. for a 24-hour interval.

0–900 0–65535

Current UAS Number of unavailable seconds in which a failed signal occurred during

the current interval. This value is updated every second for a 15-minute

interval or every a 15 min. for 24-hour intervals.

0–900 0–65535

Current BES

Number bursty errored seconds, in which 2 to 831 CRC error events

occurred during the current interval. This value is updated every second.

0–900 0–65535

Current LOFC Number of loss of frame alignment events measured during the current

interval. This value is updated every second for 15-minute interval or every

15 min. for 24-hour interval.

0–255 0–255

Current CSS

Number of seconds with one or more controlled slip events measured

during the current interval. This value is updated every second for a
15-minute interval or every 15 min. for a 24-hour interval.

0–255 0–255

24 hour

degrade
minute

Total number of degraded minutes in the current 24-hour interval. A
degraded minute is a minute in which the BER exceeded 1×10

-6

. This

value is updated every minute.

– 0–1440

24 hour last

degrade
minute

Total number of degraded minutes in the last 24-hour interval. This value

is updated every 24 hours.

– 0–1440

Advertising