Appendix A Interface Connector Specifications

Installation and Operation Manual

A-2

DTE Interface Connectors

ASMi-52 Ver. 2.5

Table A-1. V.35, X.21 and RS-530 Connector Pinouts (Cont.)

V.35

RS-530

X.21

Description

34-Pin

DB-25

DB-15

Signal

Function

Pin

Circuit

Pin

Circuit

Pin

Circuit

(Function)

Data Set
Ready

E DSR

107

6

22

CC(A)

CC(B)

A positive level from ASMi-52
when power is on, and ASMi-52
is (a) not in DIGITAL LOOP

mode, or (b) has not received a
REMOTE LOOPBACK signal
from the remote unit.

Data
Terminal
Ready

H DTR

108

20

23

CD(A)

CD(B)

Not

used

Carrier
Detect

F DCD

109

8

10

CF(A)

CF(B)

5

12

I(A)

I(B)

(Indication)

A positive level from ASMi-52,
except when a loss of the

received signal is detected or
when Data Set Ready is
negative.

External

Transmit
Clock

U

W

SCTE(A) 113

SCTE(B) 113

24

11

DA(A)

DA(B)

7

14

(A)

(B)

A serial data rate clock input

from the data source. Positive
clock translations must
correspond to data

transmissions.

Transmit

Clock

Y

a

SCT(A) 114

SCT(B) 114

15

12

DB(A)

DB(B)

6

13

S(A)

S(B)
(Signal
Timing)

A transmit data rate clock for

use by an external data source.
Positive clock translations
correspond to data translations.

Receive
Clock

V

X

SCR(A)
115

SCR(B)
115

17

9

DD(A)
DD(B)

A receive data rate clock output
used by an external data sink.

Positive clock translations
correspond to data translations.

Local Analog
Loop

L and j

18

LL

A control signal input, which,
when on, sets ASMi-52 into

Local Analog Loopback (V.54
Loop 3).

Remote
Digital Loop

N and h

21

RL

A control signal input which,
when on, commands

ASMi-52 to send a remote
Loopback command (V.54 Loop
2) to the remote ASMi-52.

Test
Indicator

n and k

25

TM

A Control Signal output from
ASMi-52; positive during any

test mode.

Advertising