Installation and Operation Manual

Chapter 6 Troubleshooting and Diagnostics

ASMi-52 Ver. 2.5

Testing ASMi-52

6-23

To activate the remote loopback at the SHDSL repeater:
1. From the Diagnostics menu, select Repeater Test (Main menu > Diagnostics

> Repeater Test).

The Repeater Test menu appears (see

Figure 6-26

).

2. From the Repeater Test menu, select Repeater Number and choose a

repeater when you intend to activate the RLB Network.

3. From the Repeater Test menu, select RLB Network.

The RLB Network value in parenthesis changes to ON. Also, an additional
parameter, Loop Timeout, is displayed.

4. Once you selected the loopback timeout, select Save to activate the RLB

Network.

The RLB at the repeater is initiated.

Data

Local ASMi-52

Repeater 1

Repeater 2

Data

Clock

Clock

Line

Interface

Customer

Interface

Customer

Interface

Network

Interface

Network

Interface

Transmit

Receive

Local

DTE

Glue

Logic

Figure 6-25. Remote Digital Loopback at the SHDSL Repeater

ASMi-52

Repeater Test

1. RLB Network

(ON)

2. Loop Timeout(min)[0 - 4095] ... (5)
3. Repeater number

> (1)

4. Save

>

ESC-prev. menu; !–main menu ; &–exit

Figure 6-26. Repeater Test Menu

Deactivating the Loopbacks

To deactivate a running loopback:
• From the Local or Remote Test menu, type the number corresponding to the

loopback in progress to change its value from ON to OFF and choose Save.

The TST indicator turns off.