Table 3-2: Waveform parameter icons

Element

Description

Element

Description

Displays the file name of the

waveform, pattern, or seĆ

quence file loaded for output.

Note: use the View button to

display the loaded waveform.

Displays the digital output and

marker signal minimum and

maximum voltage settings.

Displays the lowpass filter

setting through which the

waveformis passed.

Indicates that the channel

output is enabled or disabled.

If the switch is shown open,

that channel output is disĆ

abled.

Displays the peakĆtoĆpeak

signal amplitude setting.

Indicates that the marker

output is enabled. Marker

outputs are always enabled.

Displays the signal offset

setting.

Table 3-3: Setup bottom menu buttons

Bottom menu

button

Description

Waveform/Sequence

Displays the side menu for loading, viewing, and editing waveform

files, and for entering the FG mode main screen.

Vertical

Displays the Vertical side menu for setting waveform peakĆtoĆpeak

amplitude, offset, lowpass filter, marker, and other output parameters.

Horizontal

Displays the Horizontal side menu for setting the clock source, clock

frequency, and marker signal delay parameters.

Run Mode

Displays the Run Mode side menu for setting the instrument run mode.

Refer to the Run Modes section on page 3-37 for an explanation of the

different run modes.

Trigger

Displays the Trigger side menu for setting trigger source, slope, level,

external trigger impedance, and interval parameters.

Save/Restore

Displays the Save/Restore side menu to save and restore setup output

parameters.