Tektronix AWG610 User Manual

Page 385

Advertising
background image

Appendix B: Performance Verification

AWG610 Arbitrary Waveform Generator User Manual

B-25

ББ

ББ

DMM

50 W BNCĂcoaxialcable

InputĂconnector

+ĂBNCĆtoĆdualbanana adapter

+Ă50 W BNCĂcoaxialĂcable

AWG610 Arbitrary Waveform Generator

CH1ĂoutputĂconnector

+ĂSMA(Ma)ĆBNC(Fe) adapter

+ĂBNC 50 WĂprecision terminator

+Ă50 WĂBNC coaxialcable

Figure B-9: Amplitude accuracy initial test hookup

2. Set the DMM controls as follows:

Mode . . . . . . . . . . . . . . . . . . . . . . . . . . VDC
Range . . . . . . . . . . . . . . . . . . . . . . . . . Auto
Input . . . . . . . . . . . . . . . . . . . . . . . . . . Front

3. Follow the substeps below to set the AWG610 Arbitrary Waveform

Generator controls and to select the sequence file:

a. Push UTILITY (front-panel)

!System (bottom)!Factory Reset

(side)

!OK (side).

b. Push SETUP (front-panel)

!Run Mode (bottom)!Enhanced (side).

The AWG610 Arbitrary Waveform Generator is set to enhanced mode.

c.

Load the AMP1.SEQ file.

Refer to Loading Files on page B–10 for file loading procedures.

4. Push the RUN and CH1 output buttons.

The LEDs above the RUN button and CH1 output connector are on.