Awg610 test record – Tektronix AWG610 User Manual

Page 373

Advertising
background image

Appendix B: Performance Verification

AWG610 Arbitrary Waveform Generator User Manual

B-13

AWG610 Test Record

Photocopy this test record and use to record the performance test results for your
AWG610.

AWG610 Test Record

Instrument Serial Number:ą

Certificate Number:ą

Temperature:ą

RH %:ą

Date of Calibration:ą

Technician:ą

AWG610 Performance Test

Minimum

Incoming

Outgoing

Maximum

Operating Mode
Check Cont Mode

Pass/Fail

__________

__________

Pass/Fail

Check Triggered Mode (when the FORCE

TRIGGER button is pushed)

Pass/Fail

__________

__________

Pass/Fail

Check Triggered Mode (with external triggering)

Pass/Fail

__________

__________

Pass/Fail

Check Gated Mode (when the FORCE TRIGGER

button is pushed)

Pass/Fail

__________

__________

Pass/Fail

Check Gated Mode (with the gate signal when

the AWG trigger polarity is set to positive)

Pass/Fail

__________

__________

Pass/Fail

Check Gated Mode (with the gate signal when the

AWG trigger polarity is set to negative)

Pass/Fail

__________

__________

Pass/Fail

Amplitude and Offset Accuracy (Normal Out)
CH1 Amplitude

20 mV

200 mV

2 V

17.70 mV

195.0 mV

1.9680 V

__________

__________

__________

__________

__________

__________

22.30 mV

205.0 mV

2.0320 V

CH1 Amplitude

20 mV

200 mV

2 V

17.70 mV

195.0 mV

1.9680 V

__________

__________

__________

__________

__________

__________

22.30 mV

205.0 mV

2.0320 V

CH1 Offset

0 V

+1 V

-1 V

- 10.0 mV

+ 0.980 V

- 0.980 V

__________

__________

__________

__________

__________

__________

+ 10.0 mV

+ 1.020 V

- 1.020 V

CH1 Offset

0 V

+1 V

-1 V

- 10.0 mV

+ 0.980 V

- 0.980 V

__________

__________

__________

__________

__________

__________

+ 10.0 mV

+ 1.020 V

- 1.020 V

Advertising