Tektronix AWG610 User Manual

Page 403

Advertising
background image

Appendix B: Performance Verification

AWG610 Arbitrary Waveform Generator User Manual

B-43

Trigger Signal CH2

(5.35 V level)

CH1

Figure B-17: Trigger Signal (+5V check2)

8. Verify the Trigger level accuracy at –5V by following the substeps below:

a. Set the trigger level of AWG610.

H Push Level (side).
H Push –, 5 and ENTER keys in this order.

b. Set the offset level of generator.

H Push Cursor, %, &, ,

keys as the low level of a pulse to be set

to –4.65V.

c.

Verify that no waveform is displayed on the oscilloscope.

Trigger Signal CH2

(-4.65 V level)

NOTE: In step 5b this

voltage level equals

-4.65 V.

Figure B-18: Trigger Signal (-5V check1)

Advertising