Tektronix AWG610 User Manual

Page 376

Advertising
background image

Appendix B: Performance Verification

B-16

AWG610 Arbitrary Waveform Generator User Manual

AWG610 Test Record (cont.)

Instrument Serial Number:ą

Certificate Number:ą

Temperature:ą

RH %:ą

Date of Calibration:ą

Technician:ą

AWG610 Performance Test

Maximum

Outgoing

Incoming

Minimum

Marker Output
MARKER1 Low level (Set the level to -1.1 V.)

-1.2550 V

__________

__________

-0.9450 V

MARKER1 High level (Set the level to 3.0 V.)

2.750 V

__________

__________

3.250 V

MARKER1 Low level (Set the level to -1.1 V.)

-1.2550 V

__________

__________

-0.9450 V

MARKER1 High level (Set the level to 3.0 V.)

2.750 V

__________

__________

3.250 V

MARKER2 Low level (Set the level to -1.1 V.)

-1.2550 V

__________

__________

-0.9450 V

MARKER2 High level (Set the level to 3.0 V.)

2.750 V

__________

__________

3.250 V

MARKER2 Low level (Set the level to -1.1 V.)

-1.2550 V

__________

__________

-0.9450 V

MARKER2 High level (Set the level to 3.0 V.)

2.750 V

__________

__________

3.250 V

Marker Delay
Marker 1 Delay Range (0 ns to 1.5 ns)

Pass/Fail

__________

__________

Pass/Fail

Marker 1 Delay (when set to 1.5 ns delay)

1.050 ns

__________

__________

1.650 ns

Marker 2 Delay Range (0 ns to 1.5 ns)

Pass/Fail

__________

__________

Pass/Fail

Marker 2 Delay (when set to 1.5 ns delay)

1.050 ns

__________

__________

1.650 ns

Advertising