Table 3-22: Setup general parameters

Parameter

Description

HorizontalUnit

Specifies the horizontalaxis data point unit (points or time) used to

represent the position along the horizontal axis. The default setting is points.

Update Mode

Specifies when output memory is updated. In Auto the output waveform is

automatically updated in the waveform memory as you change the

waveform in the editrot. Changes are not saved to the original file, unless

you manually save the changes.

Note: Auto mode only works when the file you currently editing is also

loaded in the waveform memory.
Selecting Manual causes the instrument to update the output waveform only

when the contents of the waveform file on the disk is changed by the save

function of the editor.
In Auto mode, you cannot edit waveform while the instrument is reloading.

The longer the waveform, the longer you may have to wait to return to edit

mode. Manual mode allows faster editing when you have a large number of

points in the data file.

Cursor Link

Specifies whether to link cursor movement when two or three edit windows

are open. Selecting ON causes the cursors in the inactive windows to be

linked to their respective cursor in the active window. The default value is

Off.
If a linked cursor reaches either end of its data record before the active

window cursor, the linked cursor remains at the data record end. This can

result in changes to the relative cursor positions and edit areas between the

editor windows.

Grid

Specifies whether to display a grid. Selecting On displays a grid in all open

Graphical Waveform Editor windows. Selecting Off disables grid display.

The default value is Off. The grid is not displayed in the Tabular Waveform

Editor window or the Pattern Editor window.
The instrument automatically sets the grid interval.

Interpolation

Specifies whether to enable waveform display interpolation when the density

of points decreases due to zooming. Selecting On specifies that the

instrument use the algorithm aX

2

+ bX + c

to interpolate the waveform

level between data points.
Selecting Off displays the data point values as they are. The default value is

Off.
This function is provided to display a smooth waveform from data that

contains relatively few data points in a cycle (such as in a disk test

waveform). Note that this function may cause reduction in the linearity of

some types of waveforms, such as a ramp waveform.